This checklist can be used to ensure that all correct steps are followed during observations.
General
- Close and restart the server program (see 5)
Red Beam
- Change the date in the common camera config file (see 6.1)
- Calibrate the SOUP filter (see 6.2)
- Add new offset(s) to SOUP sequence file (see 6.5)
- Start imaging (see 5.1)
- After imaging, perform a system calibration (see 8)
- If necessary, perform a polarimetry calibration (see 6.7)
- Repeat from 4
Blue Beam
- Change the date in the common camera config file (see 6.1)
- Every 2nd day of observations, perform a rotatable filter calibration (see 7.2)
- Start imaging (see 5.1)
- Perform a system calibration at the same time as the red beam (above)
- Repeat from 3